· Fine-bore suction tip suitable for small surgical fields.
· Rigid stainless-steel construction ensures steady handling.
· Luer lock connector provides secure attachment to suction lines.
· Ergonomically shaped handle for enhanced surgeon control.
· Lightweight and balanced for long procedures under magnification.
· It can be autoclaved and reused economically.
This suction tube is indispensable in procedures involving the middle ear, mastoid, nasal cavity, or small wound sites where excess fluids can obscure the operative field.
· Cylindrical stainless-steel body with a fine internal lumen.
· Provides direct suction from the surgical site to the tubing system.
· Normally straight but may be curved slightly to provide access to deep or angled areas.
· Polished exterior for smooth insertion and easy cleaning.
· Fine, open end for micro-level suction.
· Available in multiple diameters: usually from 0.7 mm to 2 mm.
· Allows for aspiration to be performed in a gentle manner, without causing further damage to delicate tissues.
· Standardized connector fitting for secure attachment to suction tubing.
· Avoids accidental disconnections during procedures.
· Allows for the integration with regulated suction systems or manual syringes.
· Some versions feature a finger-operated vent on the tube body.
· Allows the surgeon to modulate suction power manually. This will provide exact control.
· Non-corrosive and biocompatible to be used safely in all surgical applications.
· High mechanical strength underpinning structural integrity against applied pressure.
· Polished internal lumen for consistent airflow and ease of sterilization.
· Resistant to autoclave sterilization and chemical disinfectants.
For high-precision instruments, such as a Zöllner suction tube, even micro-level imperfections can affect performance. Thus, the lumen and tip are precision-machined by CNC technology and hand-finished to eliminate burrs or irregularities.
This ensures that each suction tube delivers smooth, controlled, and laminar suction flow without fluctuations or blockages.
1. The Luer lock connector is securely attached to either a suction line or a syringe.
2. The distal tip of the suction tube is placed at the surgical site.
3. The vacuum source creates negative pressure via the lumen.
4. Fluids, debris, or blood are gently aspirated through the fine-bore tip.
5. If present, the thumb vent permits the surgeon to change suction intensity dynamically.
The precision of this mechanism makes the Zöllner suction tube perfectly suitable for microscopic surgical work, where too much suction could damage delicate tissues.
· Tip Diameter: 0.7 mm, 1.0 mm, 1.5 mm, 2.0 mm
· Length: 10 cm to 18 cm depending on application
· Configuration: Straight or slightly curved
· Connector: Standard Luer lock fitting
· Optional Vent: Available with or without thumb control
· Standard Zöllner Tube: Basic straight version with Luer lock connector.
· Curved Zöllner Tube: Allows access to deeper or angled areas; middle ear.
· Vented model: Allows the suction strength to be manually controlled.
· Non-Vented Model: Provides for continuous, uninterruptive suction.
This versatility makes the Zöllner suction tube adaptable to many kinds of microsurgery.
· Tympanoplasty and stapedectomy.
· Clearing blood or fluid from the ear canal or middle ear.
· Removal of debris during mastoid exploration.
· Aspiration during septoplasty or sinus surgery.
· Clearing the mucus or blood from enclosed nasal passages.
· Used under operating microscopes for precision in suction control.
· Assists in the removal of fluid or irrigation solution without pressure surges.
· Clearing small wound sites during delicate tissue adjustments.
The precision and control of the Zöllner tube make it indispensable wherever fine, localized suction is required.
· High Precision: The fine tip enables exact suction control around delicate areas.
· Secure Connection: Luer lock prevents accidental disconnection.
· Minimal Tissue Trauma: Smooth, narrow lumen precludes damage to fragile tissues.
· Controlled Suction Flow: Optional vent allows instant modulation.
· Ergonomics: Light, perfectly balanced for prolonged work under magnification.
· Durability: Constructed from corrosion-resistant surgical stainless steel.
· Reusability: Fully autoclavable, reducing long-term costs.
These attributes together make the Zöllner suction tube a hallmark of microsurgical excellence.
· Check the instrument for blockages and other abnormalities.
· Verify that the luer is tightened properly without leaks.
· Attach to suction tubing or syringe.
· Check that the seal is air-tight.
· Hold the tube like a pen for controlled movement.
· Place the fine tip near the target area without applying direct pressure.
· On vented models, adjust suction strength with the thumb.
· Keep your hand steady to avoid displacing tissue.
· Disconnect and flush the lumen with sterile saline.
· Avoid bending or striking the fine tip.
· Keep the suction pressure within recommended limits.
· Clean immediately after use to prevent lumen blockage.
Proper technique means safety and longevity of the instrument.
· Rinse with water immediately after use, removing biological material.
· Clean the lumen using a soft brush or syringe flush.
· Employ an ultrasonic cleaner for thorough internal decontamination.
· Dryouracil completely before sterilization.
· Autoclave at 134°C for 3–5 minutes.
· Avoid overexposure to moisture after autoclaving.
· Check for proper tip alignment and patent lumens before storage.
· Store in a padded instrument tray or case.
· Protect the fine tip against mechanical damage.
Proper cleaning and sterilization ensure both functionality and hygiene standards are preserved.
· Do not use excessive suction in small, confined areas.
· Avoid pointing the tip toward fragile tissues including membranes or vessels.
· To be avoided in case of obstructed or sharply angulated lumen.
· Make sure suction tubing fits properly and does not leak.
· Handle under magnification for accuracy in microsurgical settings.
Observing these precautions ensures safe and effective operation.
Instrument | Key Features | Primary Use |
| Zöllner Suction Tube | Fine-bore, Luer lock, optional vent | Middle ear, otologic microsurgery |
| Frazier Suction Tube | Larger, angled tip, removable stylet | General ENT, neurosurgery |
| Yankauer Suction Tube | Bulky, single rigid tip | General surgical suction |
Rosen Suction Tube | Fine-bore, shorter, no Luer lock | Ear procedures, limited control |
By comparison, the Zöllner tube has a secure connection, fine lumen, and accurate modulation of suction, especially useful during middle ear and microsurgical procedures.
· Manufactured under the ISO 13485:2016 quality management systems.
· Precision CNC machining ensures constant lumen diameters.
· Hand finishing for burr-free tips.
· Mirror-polished surface for minimal fluid adhesion.
· 100% leak-tested for suction integrity.
Attention to such details allows each instrument to perform flawlessly and meet the exacting demands of surgeons anywhere in the world.